1/5
Climate tools screenshot 0
Climate tools screenshot 1
Climate tools screenshot 2
Climate tools screenshot 3
Climate tools screenshot 4
Climate tools Icon

Climate tools

Carel Industries S.p.A.
Trustable Ranking Icon인증완료
1K+다운로드
13MB크기
Android Version Icon2.3.3 - 2.3.7+
안드로이드 버전
4.1(22-03-2018)최신 버전
-
(0 리뷰)
Age ratingPEGI-3
다운로드
세부 정보리뷰버전정보
1/5

Climate tools의 설명

The ultimate app for air psychometrics and evaporative cooling!

What are the air characteristics given the current values of temperature and humidity? How can I calculate the mix of two air stream? What is the humidification load for my AHU? These are some of the questions this app can provide answers for, and, on top, also estimates of power saved by evaporative cooling.


There are 9 functions available inside the app:


· AIR calculates the characteristic parameters of the air by entering 2 of the following 4 values: dry-bulb temperature (DBT), wet-bulb temperature (WBT), %rh, humidity ratio. The outputs are: dew-point temperature, specific enthalpy, density, specific volume, vapor pressure, vapor density

· MIX calculates the characteristics of the mixture from the properties of two air streams (DBT, WBT, %rh, W, flow rate)

· HUMIDIFICATION LOAD 1 calculates the humidification load based on an air current upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification) and the conditions of pre-heating

· HUMIDIFICATION LOAD MIX calculates the humidification load from the mixture of 2 air streams upstream of the humidifier and a set point. The outputs are: the humidification load, the flow rate of the atomized water (only in the case of adiabatic humidification), the conditions of pre-heating, the characteristics of the mixture of the two air streams upstream of the humidifier

· DEC (Direct Evaporative Cooling) calculates the cooling, as temperature and as power, of an air stream by the evaporation of water sprayed in it

· IEC (Indirect Evaporative Cooling) calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed in a secondary air stream that does NOT mix with the primary stream. The primary and secondary streams pass through a cross-flow heat exchanger

· DEC + IEC calculates the cooling, as temperature and as power, of a primary air stream by evaporation of water sprayed both in the primary stream and in a secondary air stream. The primary and secondary streams pass through a cross-flow heat exchanger WITHOUT mixing. The secondary stream is the exhausted part of the return air. If the exhaust flow is less than the primary flow, the part of return air not exhausted is mixed with the cooled primary air after the heat exchanger.

· EVAPORATIVE COOLING calculates the additional heat rejected by a condenser coil/dry cooler when they are sprayed by water, assuming that water completely wets the exposed surface of the heat-rejection coil.

· AFTER THE AIR HUMIDIFIER IN AHU/DUCT calculates the conditions downstream of the humidifier in AHU/duct once the environment’s set point and internal sensible and latent loads are entered.

Climate tools - 버전 4.1

(22-03-2018)
다른 버전들
뭐가 새롭나- new ebooks request form

아직 평가나 리뷰가 없습니다! 첫 번째로 남겨 보세요

-
0 Reviews
5
4
3
2
1

Climate tools - APK 정보

APK 버전: 4.1패키지: com.carel.climatetools
안드로이드 호환: 2.3.3 - 2.3.7+ (Gingerbread)
개발자:Carel Industries S.p.A.권한:1
이름: Climate tools크기: 13 MB다운로드: 85버전 : 4.1출시 날짜: 2020-05-18 18:35:20최소 스크린: SMALL지원되는 CPU:
패키지 ID: com.carel.climatetoolsSHA1 서명: 49:69:A0:AC:77:5F:CF:03:80:3D:1D:61:68:3B:96:B7:F2:4A:C2:85개발자 (CN): Mauro Galvan단체 (O): Carel로컬 (L): 나라 (C): IT주/시 (ST): 패키지 ID: com.carel.climatetoolsSHA1 서명: 49:69:A0:AC:77:5F:CF:03:80:3D:1D:61:68:3B:96:B7:F2:4A:C2:85개발자 (CN): Mauro Galvan단체 (O): Carel로컬 (L): 나라 (C): IT주/시 (ST):

Climate tools의 최신 버전

4.1Trust Icon Versions
22/3/2018
85 다운로드13 MB 크기
다운로드
appcoins-gift
보너스 게임더 많은 보상을 받으세요!
더 보기